Electric Dryer Wiring Requirements
If the dryer is installed with a 4 wire electrical.
Electric dryer wiring requirements. The neutral ground conductor is permanently connected to the neutral conductor white wire within the dryer. Electric dryer circuit cable the typical cable used for a dryer circuit is 10 3 type nm cable which has three insulated wires and a bare ground wire totaling four wires in all. This plug must be used with a 120 240v receptacle. Electric dryers run on both 240 volt and 120 volt power.
The 120v is for the timer clock buzzer and other bells and whistles. You may find yourself with either a 3 wire or 4 wire electric dryer or a 3 wire or 4 wire outlet. To simultaneously produce intense heat tumble a drum and run a timer clothes dryers require special wiring. A laundry room needs at least one 20 amp circuit for receptacles serving laundry equipment.
You need beefier eight gauge wire for an industrial or heavy duty dryer that draws 40 or more amps of electric current. Although most projects call for a standard wire size certain circumstances will affect your choice. To help you understand which electrical protection goes where consider what each type of breaker was designed to do and make sure to follow the national electric code. See an electric dryer installation with a typical 240 volt electric power circuit and the dryer cord wiring system.
How to wire an electric dryer. Electric dryer circuit if you have an electric dryer it must be on a dedicated 240 volt circuit. 3 wire and 4 wire configurations for clothes dryers. This dryer is manufactured ready to install with a 3 wire electrical supply connection.
Nm cable is the wiring material used for residential electrical supply including heavy duty appliances such cas clothes dryers. Electrical connection you will be using and follow the instructions provided for it here. All receptacles must be gfci protected. An electric dryer needs its own 30 amp 240 volt circuit wired with four conductors older circuits often have three conductors.
Modern appliances require 4 conductor cord sets separate conductors or wires for line 1 line 2 ground and neutral. The wire size for an electric dryer circuit. Because the circuit is connected to a 20 amp breaker you must wire it with 3 wire 12 gauge cable. Generally this setup is safer because the current carrying neutral is not connected to.
The 240v is for the dryer s heating element. Wire size for dryer the wire size for a 30amp dryer circuit is 10awg copper. The proper dryer wire size depends on the ampacity and when the current draw is 30 amps the wire should be 10 gauge. Most electric dryers run on 240 volt power and draw 30 amps.